Description
Bench Top Unit on the Electrical Connection of a Refrigerant Compressor
- Simulation: Simulation of a refrigeration circuit with compressor, collector, and 2 manual valves
- Components: Electric starting devices, electric motor protection, and safety devices for compressor operation
- Front Panel: Includes controls and displays, circuit diagram, and laboratory sockets
- Connections: Delivery and intake side of compressor fitted with adjustable pressostats and manometers
- Refrigerant: CFC-free refrigerant R134a
- Compressor: Hermetic piston compressor with refrigerating capacity of 252W at 0/32°C
Pressostat Adjustments:
- Delivery side trigger pressure: 8…32bar
- Switching differential: 4…10bar
- Intake side trigger pressure: -0.2…7.5bar
- Switching differential: 0.7…4bar
Measurements:
- Manometer: -1…9bar / -1…24bar
- Thermostat: -5…35°C
Dimensions and Weight:
- Size (L×W×H): 900×400×650 mm
- Weight: approx. 35 kg